cast-in-place values can be used for 4 in. . 1. No.320 - 34''H x 29''W x 24''Deep Platform. Also see pier defects cited at 3285.311 - REQUIRED PERIMETER SUPPORTS. Mobile home piers must be able to support loads up to 8,000 pounds. the floor joists must be maintained. (2) Manufactured piers must be rated at least to the loads required to safely support the dead and live loads, as required by 3285.301, and the installation instructions for those piers must be consistent with Tables 1, 2, and 3 to this section. (ii) Pressure treated lumber is to be treated with a water-borne adhesive, in accordance with AWPA Standard U1-04 (incorporated by reference, see 3285.4) for Use Category 4B ground contact applications. The QuickJack BL-3500SLX Car Lift (12-Volt DC) CE is the ultra-portable lift system for car lovers of all kinds. See 3285.202 and 3285.303, and Table to 3285.312. quickjack adjustable perimeter support for mobile homes. Adjustable from 28 to 40 with threaded rod design. On 2021-03-22 by (mod) I recently had a double wide moved Piers are not required at openings in the mating wall that are less than 48 inches in width. QuickJACK Pro A European version of the adjustable shed support, the QuickJACK Pro shed base markets itself as needing zero site prep before installing. See Table to 3285.312 for sizing of footings. The pier spacing and loads shown in the above table do not consider flood or seismic loads and are not intended for use in flood or seismic hazard areas. Place piers on both sides of mating wall openings that are 48 inches or greater in width. 2023 Discount Mobile Home Parts. Easily adjust doorways to square up openings for doors or windows to open and close better. 8. A footing must support every pier. Akron Adjustable Floor Jack (Model C-4), Akron Jacks Floor Jacks, Telescoping Jack For Temporary Support, Size Range 1'-1' 3" (2 Pack) . - Texas (2014). (d) Alternative foundation systems or designs are permitted in accordance with either of the following: (1) Systems or designs must be manufactured and installed in accordance with their listings by a nationally recognized testing agency, based on a nationally recognized testing protocol; or. [1] Section 184 Indian Home Loan Guarantee Program, U.S. Department of Housing & Urban Development, web search 1/5/2012, original source: portal.hud.gov/hudportal/HUD?src=/program_offices/public_indian_housing/ih/homeownership/184 - Quoting: [2] Native American Housing Loan Guarantee Program HUD Section 184 Loans At A Glance, FannieMae, web search 1/5/12, original source: efanniemae.com/sf/mortgageproducts/pdf/section184aag.pdf, [5] "Modular Home Construction, special defects and inspection methods" Dan Friedman, NY Metro ASHI Seminar, Holiday Inn, Crowne Plaza, White Plains NY, October 4, 1996. The piers used must be capable of transmitting the vertical live and dead loads to the footings or foundation. In general you could replace a steel lally column with a masonry support pier - both need to be on suitable footings or pads. Footings for mobile home piers: by Inspectapedia Com Moderator (mod) - when is a screw-type support pier over-extended, Typical standards such as you'll see on this page set a limit of 1 1/2 to 2-inches of screw extension measured from the top of the pyramid's screw-opening to the top of the extendable screw, in an adjustable pier installation. Piers may be offset 6 in. Expert Bail Services; Customer Comments It's an ugly problem that means you'll need a design professional, like an architect or engineer who, for a fee, will look at your structure and write an "it's ok" letter - so I suspect at the very least you're looking at a fee to do that. Jack - Quick (HP62) For use in supporting doorways and windows for manufactured housing and portable buildings. In an area of deep snow, 5-6 ft, the roof would be built to carry up to 90 pounds per square foot. Watch out: a "stabilizing" system for a doublewide or singlewide mobile home may, depending on the wind zone rating where you live, require cables and anchors that can NOT be removed without both violating your local building codes and making your home unsafe. The extra spacers will offer additional lifting height! We have no relationship with advertisers, products, or services discussed at this website. On 2021-11-28 (ii) Six inch minimum poured-in-place concrete pads, slabs, or ribbons with at least a 28-day compressive strength of 3,000 pounds per square inch (psi). 1. These supports are welded to I-beams and lag bolted to rim joist. The pier spacing and loads shown in the above table do not consider flood or seismic loads and are not intended for use in flood or seismic hazard areas. Now the county wants us to provide them weight bearing information for this mobile home. QuickJack is very easy to set up, even if you've never purchased a car lift or worked with hydraulics before. Single-stack concrete block pier loads must not exceed 8,000 lbs. An insulated foundation is permitted above the frost line, when all relevant site-specific conditions, including soil characteristics, site preparation, ventilation, and insulative properties of the under floor enclosure, are considered, and the foundation is designed by a registered professional engineer or registered architect: The sizing and layout of footings depends on the load-bearing capacity of the soil, footings, and the piers. 2 of surface coated. I'm being told that I need to replace 21 of the piers because they are overextended. Roll, No.548 - Pro Flex Tripolymer Caulking Sealan, No.552 - Coil And Fin Cleaner And Degreaser, No.555 - Sta'-Put Spray Adhesive Remover 12O, No.556 - Sta'-Put High Temp Adhesive 15Oz, No.557 - Liquid Nails For Interior Projects, No.558 - Liquid Nails For Subfloors (Exterio, No.560 - Dap Elastomeric Latex Sealant 10.1O, No.562 - Sheet Metal Screws, Hex Head #8 Gau, No.563 - Sheet Metal Screws, Hex Head #8 Gau, No.564 - White Sheet Metal Screws Hex Head 8, No.565 - White Sheet Metal Screws Hex Head 8, No.566 - White Sheet Metal Screws, Hex Head, No.567 - Dyco C-10 Hypalon Flow Seal Caulk. No.16 - Chrome Toe Touch Steel Bathtub Dra, No.17 - Empire 1/2'' Chrome Shower Arm & Fl, No.20 - Cover Plate For Single Lever Faucet, No.22 - Premier Wax Ring with Polyethylene, No.32 - 20'' x 17'' Oval Vitreous China Lav, No.33 - 20''X 17''Oval Plastic Lavatory Sin, No.34 - Better Bath 27'' x 54''Heavy Gauge, No.35 - Better Bath 32'' x 32''Heavy Gauge, No.36 - Better Bath 27'' x 54''Abs 1 Piece, No.37 - Better Bath 54''X 54''Heavy Gauge A, No.38 - Better Bath 40'' x 54''Abs 1 Piece, No.39 - Better Bath 40'' x 60''Abs 1 Piece, No.40 - Better Bath 27'' x 54''Abs 3 Piece, No.43 - Better Bath 40'' x 54''Abs 5 Piece, No.44 - Better Bath 27'' x 54''Abs 5 Piece, No.45 - Better Bath 32'' x 32''Abs 1 Piece, No.46 - Better Bath 28'' x 54'' Abs 3 Piece, No.49 - Standard Framed By-Pass Bath Door 5, No.56 - Empire or Phoenix Garden Tub Filler, No.57 - Empire Garden Tub Faucet With Showe, No.58 - Empire or Phoenix One Piece Deck Mo, No.59 - Phoenix 4'' Tub And Shower Diverte, No.60 - Empire or Phoenix 4'' Exposed Showe, No.61 - Empire or Phoenix 4'' Tub And Showe, No.62 - Empire Two Valve Faucet And Spout W, No.63 - Empire One Piece Two Valve Faucet (, No.64 - Empire One Piece Two Valve Faucet (, No.66 - Empire or Phoenix 4'' Shower Valve, No.68 - Bristol 8'' Chrome Utopia Tub Fauce, No.69 - Better Bath 40'' x 54'' Heavy Gauge, No.70 - Better Bath 27'' x 54'' Heavy Duty, No.71 - Better Bath 27'' x 54''Standard Abs, No.72 - Better Bath 40'' x 60'' Heavy Gauge, No.74 - Better Bath 42'' x 60'' Heavy Gauge, No.75 - Better Bath 54'' x 54'' Heavy Gauge, No.76 - 30'' x 39'' Aluminum Vertical Slidi, No.77 - 14'' x 21'' Aluminum Vertical Slidi, No.78 - 18'' x 21'' Aluminum Vertical Slidi, No.79 - 24'' x 21'' Aluminum Vertical Slidi, No.80 - 30'' x 21'' Aluminum Vertical Slidi, No.81 - 24'' x 24'' Aluminum Vertical Slidi, No.82 - 14'' x 27'' Aluminum Vertical Slidi, No.83 - 18'' x 27'' Aluminum Vertical Slidi, No.84 - 22'' x 27'' Aluminum Vertical Slidi, No.85 - 24'' x 27'' Aluminum Vertical Slidi, No.86 - 30'' x 27'' Aluminum Vertical Slidi, No.87 - 36'' x 27'' Aluminum Vertical Slidi, No.88 - 40'' x 27'' Aluminum Vertical Slidi, No.89 - 46 x 27 Aluminum Vertical Sliding W, No.90 - 30'' x 30'' Aluminum Vertical Slidi, No.91 - 46'' x 30'' Aluminum Vertical Slidi, No.92 - 14'' x 35'' Aluminum Vertical Slidi, No.93 - 22'' x 35'' Aluminum Vertical Slidi, No.94 - 24'' x 35'' Aluminum Vertical Slidi, No.95 - 30'' x 35'' Aluminum Vertical Slidi, No.96 - 36'' x 35'' Aluminum Vertical Slidi, No.97 - 40'' x 35'' Aluminum Vertical Slidi, No.98 - 14'' x 39'' Aluminum Vertical Slidi, No.99 - 18'' x 39'' Aluminum Vertical Slidi, No.100 - 24'' x 39'' Aluminum Vertical Slidi, No.101 - 36'' x 39'' Aluminum Vertical Slidi, No.102 - 40'' x 39'' Aluminum Vertical Slidi, No.103 - 46'' x 39'' Aluminum Vertical Slidi, No.104 - 30'' x 52'' Aluminum Vertical Slidi, No.105 - 14'' x 53'' Aluminum Vertical Slidi, No.106 - 30'' x 53'' Aluminum Vertical Slidi, No.107 - 36'' x 53'' Aluminum Vertical Slidi, No.108 - 40'' x 53'' Aluminum Vertical Slidi, No.109 - 46'' x 53'' Aluminum Vertical Slidi, No.110 - 30'' x 58'' Aluminum Vertical Slidi, No.113 - Stainless Steel Entrance & Deadbolt, No.114 - Brass Entrance & Deadbolt Combo Loc, No.119 - Combination Exterior Door With 9 Li, No.122 - 72'' x 76'' Out-Swing French Door, No.124 - Elixer 34'' x 76''Out-Swing Self St, No.125 - Kinro 30'' x 39'' Vinyl Vertical Sl, No.126 - Kinro 14'' x 21'' Vinyl Vertical Sl, No.129 - Kinro 14'' x 39'' Vinyl Vertical Sl, No.130 - Kinro 14'' x 53'' Vinyl Vertical Sl, No.131 - Kinro 24'' x 39'' Vinyl Vertical Sl, No.132 - Kinro 30'' x 27'' Vinyl Vertical Sl, No.133 - 30'' x 30'' Vinyl Vertical Sliding, No.134 - Kinro 30'' x 35-3/4'' Vinyl Vertica, No.135 - Kinro 30'' x 52'' Vinyl Vertical Sl, No.136 - Kinro 30'' x 53'' Vinyl Vertical Sl, No.137 - Kinro 30'' x 54'' Vinyl Vertical Sl, No.138 - Kinro 30'' x 58'' Vinyl Vertical Sl, No.139 - Kinro 30'' x 68'' Vinyl Vertical Sl, No.140 - Kinro 36'' x 27'' Vinyl Vertical Sl, No.141 - Kinro 36'' x 36'' Vinyl Vertical Sl, No.142 - Kinro 36'' x 40'' Vinyl Vertical Sl, No.143 - 36'' x 53'' Vinyl Vertical Sliding, No.144 - Kinro 40'' x 27'' Vinyl Vertical Sl, No.145 - Kinro 40'' x 40'' Vinyl Vertical Sl, No.146 - Kinro 40'' x 53-7/8'' Vinyl Vertica, No.147 - Kinro 46'' x 27'' Vinyl Vertical Sl, No.148 - Kinro 46'' x 39'' Vinyl Vertical Sl, No.149 - Kinro 46'' x 53'' Vinyl Vertical Sl, No.150 - Kinro 62'' x 40'' Vinyl Horizontal, No.156 - Eaton Single Pole Circuit Breaker, No.159 - Eaton Double Pole Circuit Breaker, No.164 - Homeline Quad Tandem Circuit Breake, No.167 - Freeze Free Self-Regulating Cable (, No.168 - Plastic Dish Shade Ceiling Light, No.169 - Pass & Seymour Self Contained Wall, No.172 - Self-Contained Receptacle With Inti, No.185 - Replacement Motor For Old Style Ven, No.186 - Replacement Motor For New Style Ven, No.187 - Replacement Fan Blade For Bath And, No.190 - Weatherproof Range Hood Vent With D, No.191 - Range Hood Vent For Vinyl Siding On, No.192 - Roof Cap For Vertical Fans In Mobil, No.196 - Coleman 7990.319P Circuit Board Fur, No.197 - Coleman Hot Surace Ignitor-Part # S, No.198 - Coleman Blower Motor Part 3400-311, No.200 - 4 x 8 Brown Metal Floor Register, No.202 - E7EM-017H1 Nordyne Mobile Home Elec, No.203 - MG1E-056F A Nordyne Mobile Home Gas, No.205 - M5SB-066A AW Nordyne Mobile Home Oi, No.206 - Nordyne 903075 E2/E3 Blower Motor, No.207 - Nordyne Nortek Pressure Switch-Par, No.208 - Nordyne Nortek Furnace Pressure Sw, No.209 - Nordyne Furnace Gas Valve Standing, No.211 - Nordyne Nortek furnace Gas Valve Ki, No.212 - Nordyne Gas Valve Hot Surface Ignti, No.213 - Nordyne Furnace Hot Surace Ignitor-, No.214 - Nordyne Hot Surace Ignitor-Part 90, No.215 - Nordyne Hot Surace Ignitor-Part 90, No.216 - Nordyne Combustion Motor-Part # 303, No.217 - Nordyne Combustion Motor-Part 9044, No.218 - Nordyne Combustion Motor-Part 6210, No.220 - Nordyne Combustion Motor-Part 9034, No.221 - Nordyne Ignition Control Board- Par, No.222 - Nordyne Furnace Ignition Control Bo, No.223 - Nordyne Ignition Control Board- Par, No.224 - Nordyne 902514 Circuit Breaker Retr, No.225 - Nordyne Ignition Control Board- Par, No.226 - Nordyne Nortek Furnace Transformer, No.227 - Nordyne Transformer 20Va 120Volt-Pa, No.228 - Nordyne Nortek Furnace Transformer, No.229 - Nordyne Transformer 20Va 120Volt-Pa, No.230 - Nordyne Nortek Furnace Transformer, No.231 - Nordyne Nortek Furnace Transformer, No.232 - Nordyne Transformer 30Va 120Volt-Pa, No.234 - Nordyne Nortek FurnaceRoof Jack Ass, No.235 - Nordyne Nortek Furnace Roof Jack A, No.236 - Nordyne Nortek Furnace Roof Jack As, No.237 - Nordyne Roof Jack Assembly With Sla, No.238 - Nordyne Nortek Furnace Roof Jack As, No.239 - Nordyne Nortek Furnace Roof Jack As, No.240 - Nordyne Nortek Furnace Roof Jack As, No.241 - Nordyne Nortek Furnace Transformer, No.242 - Nordyne Nortek Furnace Sequencer Pa, No.243 - Nordyne Nortek Furnace Blower Motor, No.244 - Nordyne Nortek Furnace Blower Moto, No.245 - Nordyne Blower Motor Part # 101847, No.246 - Nordyne Blower Motor Part Universa, No.247 - Nordyne Target Assembly Part 20862, No.248 - Nordyne Blower Motor Part 902128 O, No.249 - Nordyne Flow Probe Part 66929R Fur, No.250 - Nordyne Oil Burner Motor 3450 Rpm P, No.252 - Bristol New Style Utopia Stem & Bon, No.253 - Empire 8'' Chrome 2 Handle Kitchen. [Div. Load Capacity,Portable Folding Pipe Stands, Carbon Steel Body More Durable, Camco Olympian Aluminum Jack Stands, Support up to 6,000 lbs, Pack of 4 ( 44560), YOMILINK Aluminum RV Stabilizer Jacks 4 Pack with Additional Screw Nuts, Screw Jack Stands, Stabilize and Level RV Trailer Camper, Adjustable Height 11.5 to 17.5 Inch, Single Jack Withstand 6000 Lbs, YEUQWJ Adjustable Support Jack for The Floor,Post Floor Joist Jacks,Floor Beam Leveler,RV Step Stabilizer,Mini Screw Jack- Post 7" to 10" (2 Pack), EAZ LIFT Telescopic RV Jack, Set of 2 | Adjusts from 16-inches to 30-inches | Featues a 6,000 lb. 2. - whatever original roof materials were left in place We are the customerpreferredsupplierofpremium mobile home parts and accessories. $59,900. The capacity values listed have been reduced by the dead load of the concrete footing. All components are meant for heavy-duty use by serious mechanics, and a host of optional accessories make this great hoist even more versatile. (a) Piers required at mate-line supports, perimeter piers, and piers at exterior wall openings are permitted to be constructed of single open-cell or closed-cell concrete blocks, with nominal dimensions of 8 inches 8 inches 16 inches, to a maximum height of 54 inches, as shown in Figure A to this section, when the design capacity of the block is not exceeded. Arrest & Booking; Bail Process; Online Bail by Fax or Email; Release from Jail; About. See Table to 3285.312 for cast-in-place footing design by using the noted loads. 610, Arlington VA 22201 703-558-0400, [12] NYMHA, 35 Commerce Ave., Albany NY 12206-2015 518-435-9859 800-721-HOME (they want the Star Program to provide for separate assessment of manufactured homes), [13] Consumer Reports: www.consumerreports.org - special report 2/98, Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the, Domestic Building Surveys, Andrew R. Williams, Kindle book, Amazon.com. for 8 16 single stack block and 16,000 lbs. custom wooden cabinets. 1 bath. A registered professional engineer or registered architect must prepare the design, if the design loads exceed the capacity for single or double stack concrete block piers shown in footnote 4. 2221 E. Highland Rd. Pier and footing specifications that are different than those provided in this subpart, such as block size, metal piers, section width, loads, and spacing, may be used when verified by engineering data that comply with 3285.301(c) and (d) and are capable of resisting all design loads of the MHCSS. . Pier B: Interlocked double stack of solid or open cell 8x8x16 concrete blocks. Perhaps you can attach a photo of a typical cracked concrete block pierr that is supporting your home, I have been told we have cracks in about 10 cinder blocks under our doublewide. In general and historically, the maximum height from the surface of the pier to the top of the last concrete block which would be placed under a beam or girder supporting the manufactured or mobile home floor is 36 inches for a stack of single open-celled 8" concrete blocks [Pier A], or 48" for an interlocked concrete block pier - essentially a 2-block square as we illustrate here [Pier B]. Depending on soil conditions and climate a simple solid concrete pier is permitted in many local jurisdictions as the supporting base for a mobile home pier. Is this something I should be taking up with the installer to take care of? - 24 CFR 3285.307 - Perimeter support piers And example of a concern with some much-older mobile homes is that the original walls were framed with 1x3 or 2x3 lumber - and might need reinforcement if an owner is adding the weight of a gabled roof over the original home. See Table to 3285.312for cast-in-place footing design by using the noted loads. On 2021-04-27 vertical and in alignment. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.